Sale!

Q5 Multi-Parameter Veterinary Monitor

Ex-demo Q% sale!  Q5 Multi-Parameter Veterinary Monitor- Looking to purchase accessories for the Q5 – CLICK HERE 
  • Hidden
SKU: N/A

All of our Pre-owned & Ex-demo Equipment comes with 90 days warranty and will be serviced/checked prior to delivery.

These monitors and modules are all ex-demo and come with 90 days warranty from the date of delivery.

Product Description
The Q5 is a modular monitor which allows immediate access to comprehensive patient data. Multi-Parameter modules enable you to customise your monitoring to specific patient requirements. The plug-and-play design and intuitive navigation is convenient for clinicians to set up and start monitoring patients easily.

To be able to measure the CO2 a sample of 60-100ml of expired gas is taken from the anaesthetic circuit per minute. This sample is then leaked into the environment when appropriate scavenging isn’t used. We recommend using the CO2 exhausts to minimise risk to pregnant members of staff and these are as standard added to our quotes. Please ask your territory manager for more information if you are unsure or would like to discuss further.

Product Features

  • 12.1” Anti-glare colour TFT LCD display
  • Standard touch-screen configuration with knob and backlight button, also support mouse and keyboard input.
  • Independent Physiological and technical, visual and audio alarm system.
  • Heart rate goes up to 350bpm
  • Standard Configuration of 3-lead ECG, RESP, NIBP, SpO2, PR, Temp.
  • Two standard module slots supporting plug and play for modules including IBP, TEMP, BLT EtCO2 and AG etc.
  • Abundant extension interfaces including Nurse call socket, VGA port, and USB port etc.
  • 10 channel waveforms on display screen
  • Rolling Stand or Wall Mount available.
  • Warranty – Monitor: 1 year Accessories: 6 months
  • Optional Configuration : Nellcor, SpO2, IBP, TEMP Recorder Mainstream/ Sidestream/Microstream, BLT EtCO2 Mainstream/ Sidestream, AG.
  • Optional Patient Data Record: The patient data recorded in our Q5 can either be printed out by a desktop printer or reviewed on a Windows based computer software.

Size & Weight
Size: 318mm×264mm×152mm
Weight:≤4.5kg
Standard module slot:2

Display:
12.1″ Color TFL-LCD
Resolution: 800×600pixels

Power supply:
Power voltage: AC 100~240v 50/60Hz
Input Current: 1.1~0.5A
Safety class: Category I

Battery:
Type: Rechargeable lithium-ion battery
Operating time under the normal use and full charge:
≥210minutes
Recorder (Option)
Paper width: 50 mm (1.97 in)
Paper length: 15m
Paper Speed: 12.5/25/50(mm/sec)
Traces: Maximum 3 tracks
Recording way: Real-time recording, Periodic recording, Alarm
recording

Alarm
Level: Low, medium and high
Indication: Auditory and visual
Patient Physiological alarm light colour: Yellow & Red:
Equipment Technical Alarm Light colour: Blue
Supports Pitch Tone and multi-level volume

Input device
Touchscreen: standard config
Knob: standard config
Mouse7 & Keyboard input: Support

Trend & Reviewing:
Trend: Lond trend:168h, minimum resolution is 1min
(store when the power goes off )
High-resolution trend:2h, minimum resolution is 5s
NIBP measurement reviewing: 1000 groups
ARR event: 128 groups of ARR event and the associated
waveform.
Alarm events: 128 groups of parameter alarm events and
associated parameter
Waveform at the alarming moment
Full Disclosure waveform: 96 hours for three waveforms (with 4G SD
card)

Safety:
IEC60601-1 Approved, CE marking according to MDD93/42/EEC
Performance:

ECG
Lead type 3 lead: I, II, III
Five lead: I, II, III, aVR, aVL, aVF, Vx
Gain: 2.5 mm/mV(×0.25), 5 mm/mV(×0.5), 10 mm/mV
(×1),20 mm/mV(×2), 40 mm/mV(×4), Auto
CMRR: Diagnostic mode ≥ 89 dB
Monitor mode ≥ 105 dB
Surgery mode ≥ 105 dB
Frequency response (-3d):
Monitor mode 0.5~40Hz
Surgery mode 1~25Hz
Diagnostic mode 0.05~150 Hz
Input impedance: ≥5.0 Mohm
ECG signal range: ±5%
Baseline recovery Monitor mode: ≤ 3 s; Surgery mode: ≤ 1 s
Input impedance ≥ 5.0 MΩ
ECG signal range ± 10.0 mV
Electrode offset potential ± 500 mV
Patient leakage current < 10 uA
Standardizing signal one mV ± 5%
Indication of electrode separation Every electrode (exclusive of RL)
Sweep speed 12.5 mm/s, 25 mm/s, 50 mm/s

HR
Measurement range 10 bpm to 350 bpm
Resolution 1 bpm
Accuracy ±1% or ±1 bpm, whichever is greater
ST segment
Measurement range -2.0 mV to +2.0 mV
Accuracy -0.8 mV to +0.8 mV: ±0.02 mV or ±10%, whichever is
greater; Over ±0.8mV: unspecified
Resolution 0.01mV

Resp
Measurement method Thoracic impedance
Lead Selected from Ⅰ (RA-LA) or Ⅱ (RA-LL);
Default: Ⅱ
Gain ×0.25, ×1,×2,×4
Bandwidth 0.25 Hz to 2.0Hz(-3dB)
Sweep speed 6.25mm/s, 12.5mm/s, 25mm/s
Measurement range 0 rpm to 150 rpm
Resolution 1 rpm
Accuracy ±2 rpm
Delay of apnea alarm 10s, 15s, 20s, 25s, 30s, 35s, 40s, 45s, 50s,
55s, 60s

NIBP
Measurement way Automatic oscillometry
Measurement range(mmHg) Horse 10~270 mmHg
Dog 10~235 mmHg
Cat 10~135 mmHg
Cuff pressure range: 0 mmHg to 280 mmHg
Resolution 1 mmHg
Pressure accuracy
Static: ±3 mmHg
Clinic: Average error: ±5 mmHg, standard deviation: ≤8 mmHg
Unit mmHg, kPa

BLT SpO2
Measurement range 0% to 100%
Resolution 1%
Accuracy 70% to 100%: ±2%
0% to 69%: unspecified

PR
Measurement range 20bpm to 250 bpm
Resolution 1 bpm
Accuracy ±1% or ±1 bpm, whichever is the greater
Nellcor SpO2
Measurement range 0% to 100%
Resolution 1%
Accuracy 70% to 100%: ±2%(horse/dog)
70% to 100%: ±3%(cat)
0% to 69%, unspecified

PR
Measurement range 20 bpm to 300 bpm
Accuracy 20 bpm to 250 bpm: ±3 bpm
251 bpm to 300 bpm: unspecified
Resolution 1 bpm

TEMP
Measurement way: Thermal resistance way
No. of channels 8
Measurement Range 0.0℃~50.0℃ (32℉~122℉)
Accuracy 0.0℃-50.0℃: ±0.1℃ (not including the probe)
Resolution 0.1℃
Unit: Centigrade (℃), Fahrenheit (℉)

IBP
No. of channels 8
Sensitivity of transducer 5uV/V/ mmHg, ±2%
Impedance of transducer 300Ω to 3000Ω
Measurement range -50 mmHg to +300 mmHg
Resolution 1mmHg
Unit mmHg, kPa, cmH2O
Accuracy ±4 mmHg or ±4% of the reading, whichever is the
greater (inclusion of transducer)
Kinds of Measurement ART, PA, CVP, RAP, LAP, ICP
Options of range: RT 0〜300 mmHg, PA 0〜20 mmHg,CVP 0〜30
mmHg, LAP 0〜50 mmHg, RAP 0〜80 mmHg, ICP AUTO

ETCO2 Sidestream
Measurement way Infrared spectrum
Measurement range 0.0 % to 13.1 % (0 mmHg to 99.6 mmHg)
Resolution 1mmHg
Unit %, mmHg
Accuracy <5.0 %, ±0.3 % (±2.0 mmHg)
≥5.0 %, <±10 % of the reading
Measurement range of awRR 0 rpm to 150 rpm
Calibration Offset calibration, auto/ manual; gain calibration

ETCO2 Mainstream
Warm up time: Capnogram displayed in less than 15 s, at an ambient temperature of 25℃, full specifications within 2 minutes.
Measurement range: 0% to 19.7 %(0 mmHg to 150 mmHg)
Resolution: 0.1% or 1mmHg
Rise time <60ms
Unit: %, mmHg, kPa
Accuracy: 0 mmHg to 40 mmHg, ±2 mmHg
41 mmHg to 70 mmHg, ±5% of reading
71 mmHg to 100 mmHg, ±8% of reading
101 mmHg to 150 mmHg, ±10% of reading

ETCO2 Microstream
Warm up time: Capnogram displayed in less than 20 s, At an ambient temperature of 25℃, full specifications within 2 minutes.
Measurement range 0% to 19.7 %(0 mmHg to 150 mmHg)
Resolution 0.1% or 1 mmHg
Unit %, mmHg, kPa
Accuracy :( 760mmHg,temperature is 25℃)
0 mmHg to 40 mmHg, ±2 mmHg
41 mmHg to 70 mmHg, ±5% of reading
71 mmHg to 100 mmHg, ±8% of reading
101 mmHg to 150 mmHg, ±10% of reading
(when RR >80 rpm, all the range is ±12% of reading)
Gas temperature at 25℃
Total time of system response <3s

Anesthetic Gas
Measurement way: Infrared spectrum
Measurement mode: Mainstream, Sidestream
Measurement parameters: CO2, N2O, agent(ISO, ENF, SEV, HAL,
DES)
Resolution: 1%
Calibration: Room air calibration performed automatically
when changing airway adapter (<5s)
Warm up time: < 10s. full accuracy within 1min
Measurement range and accuracy of gas
Gas Range (%) Accuracy1)
CO2 0 to 15 ±(0.3%ABS+4%REL)
N2O 0 to 100 ±(2% ABS+5% REL)
ISO,ENF,HAL 0 to 8 ±(0.2%ABS+10%REL)
SEV 0 to 10 ±(0.2%ABS+10%REL)
DES 0 to 22 ±(0.2%ABS+10%REL)
awRR measurement range from 0 rpm to 150 rpm
awRR measurement accuracy ±1 rpm

Options:Q5 – Full Spec (incl sidestream CO2), Q5 – NIBP, ECG, SPO2, TEMP, HR, Q5- Multigas module (including C02 monitoring and accessories )

At PSS we pride ourselves on our customer service and are happy to offer as much help as needed regardless of the query size.
We have an ethos of providing the best quality products at affordable prices and fully supporting them with our own team of highly skilled and experienced technicians and engineers.

Our Price Promise:
We aim to offer the most competitive price, but if you can buy the same item elsewhere for a better price let us know and we will try to match or better the price.

Demos/Loans:
Picking equipment from a website can be quite a challenge. We can visit your practice, so you can sample our products and discuss your needs with one of our team.

How To Order:
You don’t have to pay now. Many of our customers have accounts open with us as they like to be invoiced later, instead of paying now.

You can order:
Online: You can order online and select the invoicing option that suits you
Email: info@photonsurgicalsystems.co.uk
Phone: 01452 347101

Backorders:
We keep most items in stock and will aim to despatch the next day to you. Pre-owned items will be serviced and checked prior to being shipped as quickly as we can to you. However, special-order items / made to order items may take up to 4 weeks. Once an order is placed a member of our team will be in contact to keep you informed of estimated delivery dates.

Related Products

No results found.
Share This